SC-6DS,SC-10DS and SC-16DS
DIRECT STEAM CONVECTION STEAMER
INSTALLATION OPERATION MAINTENANCE
BLODGETT OVEN COMPANY
www.blodgett.com
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 658-6600 Fax: (802) 864-0183
S00048 Rev C (12/08)
Vedere la pagina 0
1 2 3 4 5 6 ... 11 12

Sommario

Pagina 1 - SC-6DS,SC-10DS and SC-16DS

1 SC-6DS,SC-10DS and SC-16DS DIRECT STEAM CONVECTION STEAMER INSTALLATION – OPERATION – MAINTENANCE BLODGETT OVEN C

Pagina 2

10 6.0 COOKING CHART The following table lists suggested cooking times and weights. These times, which will vary depending on initial product tempe

Pagina 3 - DESCRIPTION PAGE

11 PRODUCTS TO BE COOKED IN PERFORATED PANS Product Timer Setting in Minutes Weight Per Pan Clams Frozen Fresh, Cherrystone 10 - 12 5 - 6 3 Doz

Pagina 4 - 1.0 SERVICE CONNECTIONS

12 PRODUCTS TO BE COOKED IN PERFORATED PANS Product Timer Setting in Minutes Weight Per Pan Brussel Sprouts, Frozen 6 5 Lb Cabbage, Fresh, 1/6 Cut 8 5

Pagina 5

2 IMPORTANT NOTES FOR INSTALLATION AND OPERATION It is recommended that this manual be read thoroughly and that all instructions be followed carefu

Pagina 6

3 TABLE OF CONTENTS DESCRIPTION PAGE Important Notes 2 1.0 Service Connections 4 2.0 Installation Instructions 5 3.0

Pagina 7

4 1.0 SERVICE CONNECTIONS SELECTRICAL CONNECTION: 1/2" conduit connection to controls. 120VAC-60Hz-1PH 2 AMPSDRAIN: 2" IPS piped to open

Pagina 8

5 2.0 INSTALLATION INSTRUCTIONS Ideally an exhaust system should be located directly above the appliance to exhaust steam and heat generated by the

Pagina 9

6 INFORMATION TO STEAM FITTER 1. Each cooking compartment requires approximately 1 BHP (34.5 lbs of steam per hour) to operate satisfactorily. 2.

Pagina 10

7 Total of above = 20 + 2.2 + 3 + 2.2 + 17 + 23 + 10 + 2.2 = 79.6 feet. Since each 10 feet is equivalent to 1 psi pressure loss, 79.6 feet is equivale

Pagina 11

8 3.0 OPERATING INSTRUCTIONS CAUTION: Live steam and accumulated hot water in the compartment may be released when the door is opened START-UP S

Pagina 12

9 4.0 PERIODIC MAINTENANCE Never spray water into electric controls. CLEANING 1. Keep exposed cleanable areas of unit clean a