Vedere la pagina 0
1
BLP-G
GAS FLOOR MODEL BRAISING PAN WITH
ELECTRIC POWER TILT
INSTALLATION OPERATION MAINTENANCE
BLODGETT OVEN COMPANY
www.blodgett.com
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 658-6600 Fax: (802) 864-0183
S00069 Rev B (10/05)
Vedere la pagina 0
1 2 3 4 5 6 ... 16 17

Sommario

Pagina 1 - ELECTRIC POWER TILT

1 BLP-G GAS FLOOR MODEL BRAISING PAN WITH ELECTRIC POWER TILT INSTALLATION – OPERATION – MAINTENANCE BLODGETT OVEN

Pagina 2

10 TILTING THE BRAISING PAN 1. DO NOT try to tilt braising pan with lid down. 2. Make sure the receiving pan is in place. 3. To tilt braising p

Pagina 3 - DESCRIPTION PAGE

11 4.0 PERIODIC MAINTENANCE WARNING: Disconnect the power supply to the appliance before cleaning or servicing. CLEANING After each use, allow

Pagina 4 - 1.0 SERVICE CONNECTIONS

12 CAUTION: The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance. ADJUSTMENTS All tilting braising

Pagina 5

13 5.0 COOKING GUIDELINES The guidelines given below are suggested quantities, temperature settings, and estimated numbers of orders per load and p

Pagina 6

14 ITEM PORTION TEMP (F) BATCH/HR BLP-30G PER LOAD QTY PORTIONS BLP-40G PER LOAD QTY PORTIONS SAUCES, GRAVIES, SOUPS Brown Gravy

Pagina 7

15 ITEM PORTION TEMP (F) BATCH/HR BLP-30G PER LOAD QTY PORTIONS BLP-40G PER LOAD QTY PORTIONS DESSERTS, PUDDINGS, SWEET SAUCES Bu

Pagina 8 - THERMOSTAT

16 ITEM PORTION TEMP (F) BATCH/HR BLP-30G PER LOAD QTY PORTIONS BLP-40G PER LOAD QTY PORTIONS MEAT-POULTRY (continued) TURKEY Off

Pagina 9

17 6.0 TROUBLESHOOTING Burners do not come on: 1. Gas supply to unit is “OFF”. 2. Manual shut off valve is “OFF”. 3. Thermostat is not turned

Pagina 10

2 IMPORTANT NOTES FOR INSTALLATION AND OPERATION It is recommended that this manual be read thoroughly and that all instructions be followed careful

Pagina 11

3 TABLE OF CONTENTS DESCRIPTION PAGE Important Notes for Installation and Operation ...

Pagina 12

4 1.0 SERVICE CONNECTIONS 1.0 [26]29.5 [750]6[152] MINIMUM23.5 [597]OPTIONAL FAUCETPOUR PATHCA33[838]37[940]HH KH4.0 [101]7.0 [178]LMB19.25[489]DE

Pagina 13

5 2.0 INSTALLATION INSTRUCTIONS UNPACKING Immediately after unpacking, check for possible shipping damage. If the tilting braising pan is found t

Pagina 14

6 Ventilation must be provided in accordance with local codes, or in the absence of local codes, with ANSI/NFPA 96 Standard for Ventilation and Fire

Pagina 15

7 GAS CONNECTIONS All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases. The gas inlet is

Pagina 16

8 3.0 OPERATION INSTRUCTIONS BEFORE FIRST USE CAUTION: Do not attempt to operate this unit in the event of a power failure. Using a non-corros

Pagina 17

9 START-UP PROCEDURE 1. Open manual gas shutoff valve. 2. Ensure that the braising pan is in the DOWN position. 3. Turn on power switch. 4. Tu